Meister Strömungstechnik GmbH

Product category
03

Flow monitors and Flow indicators for Oil (viscosity compensated)

8 products found.
  • DKG-1

    Flow monitor and indicator for oil


    Operation:

    The flow monitors and indicators type DKG-1 operate with the float measuring principle.

     

    Specification:

    for oils (0,1 - 90 l/min)

    Viscosity: 30 - 600 cSt

    Operating temperature max.:
    120°C (opt. 160°C)

    Operating pressure max.:
    PN 10 bar

    Display: Sight glass

  • DKG-2

    Flow monitor and indicator for oil


    Operation:

    The flow monitors and indicators type DKG-2 operate with the float measuring principle.

     

    Specification:

    for oils (0,5 - 8 l/min)

    Viscosity: 30 - 600 cSt

    Operating temperature max.:
    120°C (opt. 160°C)

    Operating pressure max.:
    PN 16 bar

    Display: Sight glass

  • DKM-1

    Flow monitor for oil


    Operation:

    The flow monitors type DKM-1 operate with the float measuring principle.

     

    Specification:

    for oils (0,5 - 110 l/min)

    Viscosity: 30 - 600 cSt

    Operating temperature max.:
    120°C (opt. 160°C)

    Operating pressure max.:
    PN 250 bar (brass)
    PN 300 bar (st. st.)

  • DKM-2

    Flow monitor for oil


    Operation:

    The flow monitors type DKM-2 operate with the float measuring principle.

     

    Specification:

    for oils (0,5 - 7 l/min)

    Viscosity: 30 - 600 cSt

    Operating temperature max.:
    120°C (opt. 160°C)

    Operating pressure max.:
    PN 300 bar (brass)
    PN 350 bar (st. st.)

  • DKM/A

    Flow monitor and indicator for oil


    Operation:

    The flow monitors and indicators type DKM/A operate with the float measuring principle.

     

    Specification:

    for oils (0,1 - 110 l/min)

    Viscosity: 30 - 600 cSt

    Operating temperature max.:
    120°C (opt. 160°C)

    Operating pressure max.:
    PN 250 bar (brass)
    PN 300 bar (st. st.)

    mechanical display

  • DKM/A-2

    Flow monitor and indicator for oil


    Operation:

    The flow monitors and indicators type DKM/A operate with the float measuring principle.

     

    Specification:

    for oils (0,5 - 7 l/min)

    Viscosity: 30 - 600 cSt

    Operating temperature max.:
    120°C (opt. 160°C)

    Operating pressure max.:
    PN 250 bar (brass)
    PN 300 bar (st. st.)

    mechanical display

  • DKME

    Flow monitor for oil


    Operation:

    The flow monitors type DKME operate with the float measuring principle.

     

    Specification:

    for oils (1 - 80 l/min)

    Viscosity: 30 - 600 cSt

    Operating temperature max.:
    120°C (opt. 160°C)

    Operating pressure max.:
    PN 250 bar (brass)
    PN 300 bar (st. st.)

  • DKME/A

    Flow monitor and indicator for oil


    Operation:

    The flow monitors and indicators type DKME/A operate with the float measuring principle.

     

    Specification:

    for oils (1 - 80 l/min)

    Viscosity: 30 - 600 cSt

    Operating temperature max.:
    120°C (opt. 160°C)

    Operating pressure max.:
    PN 250 bar (brass)
    PN 300 bar (st. st.)

    mechanical display

8 products found.